summaryrefslogtreecommitdiff
path: root/tools/perf/scripts/python/bin
diff options
context:
space:
mode:
authorLadislav Michl <ladis@linux-mips.org>2017-08-25 07:39:16 +0200
committerJonathan Cameron <Jonathan.Cameron@huawei.com>2017-09-03 18:10:31 +0100
commitfe895ac88b9fbdf2026f0bfd56c82747bb9d7c48 (patch)
treea79d63def40b36d421b6b8d7d44d0802802bee8f /tools/perf/scripts/python/bin
parentd1c11dc27e3282e787406290ead5926bb7bb4579 (diff)
downloadkernel-fe895ac88b9fbdf2026f0bfd56c82747bb9d7c48.tar.gz
iio: adc: ti-ads1015: add 10% to conversion wait time
As user's guide "ADS1015EVM, ADS1115EVM, ADS1015EVM-PDK, ADS1115EVM-PDK User Guide (Rev. B)" (http://www.ti.com/lit/ug/sbau157b/sbau157b.pdf) states at page 16: "Note that both the ADS1115 and ADS1015 have internal clocks with a ±10% accuracy. If performing FFT tests, frequencies may appear to be incorrect as a result of this tolerance range.", add those 10% to converion wait time. Cc: Daniel Baluta <daniel.baluta@gmail.com> Cc: Jonathan Cameron <jic23@kernel.org> Signed-off-by: Ladislav Michl <ladis@linux-mips.org> Reviewed-by: Akinobu Mita <akinobu.mita@gmail.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Diffstat (limited to 'tools/perf/scripts/python/bin')
0 files changed, 0 insertions, 0 deletions